The diagram only shows one light per dimmer, but obviously each can handle
up to 15. The trick here is to parallel the dimmers at the switch with the
green and yellow wires. A common misconception I hear from customers is
that you can wire the white and grey wires of two dimmers with up to 30
lights and that is not the case. The right way to do it is to take the two
green wires (one from each dimmer) and connect them together and then to one
terminal of a single pole momentary switch. Do the same for the two yellow
wires and connect them to the other terminal of the pushbutton. The white
and grey wires of each dimmer should be connected to up to 15 lights each
just like in a typical PWL/PWM dimmer application.